1 AW-CFP2166 series conventional fire alarm panel is designed based on EN54 part 2&4 standard. 2 It is modularized design, the panel can expend from 1 zone to 32 zones easily. 3 It has 2 level control mode by a lock 4 It has 24VDC and 5VDC power supply output. 5 It has FIRE and FAULT signal output. 6 It has 2 general sounders output. 7 Each zone has 1 circuit detectors input. 8 Each zone can be disable by a button. 9 It has RESET button to reset the panel. 10 It has SILENCE button to stop BUZZER and SOUNDERS. 11 It has EVACUATE button to start a manual fire alarm immediately. 12 It has battery low protection function, when battery voltage lower than 21VDC, battery will be cut off automatically until the mains power is on. 13 It has an optional GSM module for fire alarm by SMS. 14 It is economic, user-friendly and easy maintenance.
Automatic conventional fire detection and fire alarm control panel.. • Control panels up to 12 zones for conventional detectors and call points use.
The Lyon Remote algorithmic addressable Control Panel is EN 54-2 and EN 54-4 standard certified according to the latest CE Directives/Regulation and can successfully overcome difficult environmental conditions, electrical interferences, electromagnetic radiate upsets, vibrations, etc. The algorithmic addressable Detection System is able to identify the device which produces the alarm or fault (sensor or call point), and allows the total configuration of the detection parameters (alarm levels, sensibility…) as well as the adaptation to the environmental conditions and the degree of dust in the sensor. In the Cofem algorithmic addressable System, the loop elements (sensors, manual call points, relay modules, masters, analogue sounders and technical signal modules) have the property of being auto-identifiable, that is to say, all of them can be installed with no need for prior manual encoding, facilitating enormously the assembly and subsequent modifications to the installation.
Conventional smoke detector for fire detection. The A30XH detector is based on the Tyndall effect (light refraction in a dark chamber) for detection of fires which generates smoke (plastic, wood, paper, etc). Features • Low section, total height less than 45 mm (including the base). • Available with high base for electrical conduit of 20 mm. • Alarm with two red LED, which makes easier the identification from any direction (360º). • Possibility to connect a remote action indicator. • Easy connection, without polarity. • Double flash LED indicates a dirty status of the detector (fast signal indicates alarm and slow indicates maintenance required). • Detector and base with easy installation, interchangeable with the entire of range A30X, and manufactured in white heat-resistant ABS. • According to EN 54-7 and CE mark according to European Regulation of Construction Products (UE) Nº305/2011.
Combined heat detector for fire detection. The detector A30XV has a double heat detection system that measures the speed of increase in temperature (rate of rise heat function), both as their absolute value (heat function), and compares it with a measure of internal reference. The rate of rise heat function allows to detect a fire in the early stages of their development, or, if this is very slow, is activated when the temperature reaches 55 °C. Features • Low section, total height less than 45 mm (including the base). • Available with high base for electrical conduit of 20 mm. • Alarm with two red LED, which makes easier the identification from any direction (360º). • Possibility to connect a remote action indicator. • Easy connection, without polarity. • Detector and base with easy installation, interchangeable with the entire of range A30X, and manufactured in white heat-resistant ABS. • According to EN 54-5 Class A2R (detectors with rate of rise heat function), and CE mark, according to the European Regulation of Construction Products (UE) N°305/2011.