ASENWARE fire alarm system

1 AW-CFP2166 series conventional fire alarm panel is designed based on EN54 part 2&4 standard. 2 It is modularized design, the panel can expend from 1 zone to 32 zones easily. 3 It has 2 level control mode by a lock 4 It has 24VDC and 5VDC power supply output. 5 It has FIRE and FAULT signal output. 6 It has 2 general sounders output. 7 Each zone has 1 circuit detectors input. 8 Each zone can be disable by a button. 9 It has RESET button to reset the panel. 10 It has SILENCE button to stop BUZZER and SOUNDERS. 11 It has EVACUATE button to start a manual fire alarm immediately. 12 It has battery low protection function, when battery voltage lower than 21VDC, battery will be cut off automatically until the mains power is on. 13 It has an optional GSM module for fire alarm by SMS. 14 It is economic, user-friendly and easy maintenance.

CLVR CONTROL PANEL

Automatic conventional fire detection and fire alarm control panel.. • Control panels up to 12 zones for conventional detectors and call points use.

LYON REMOTE CONTROL PANEL

The Lyon Remote algorithmic addressable Control Panel is EN 54-2 and EN 54-4 standard certified according to the latest CE Directives/Regulation and can successfully overcome difficult environmental conditions, electrical interferences, electromagnetic radiate upsets, vibrations, etc. The algorithmic addressable Detection System is able to identify the device which produces the alarm or fault (sensor or call point), and allows the total configuration of the detection parameters (alarm levels, sensibility…) as well as the adaptation to the environmental conditions and the degree of dust in the sensor. In the Cofem algorithmic addressable System, the loop elements (sensors, manual call points, relay modules, masters, analogue sounders and technical signal modules) have the property of being auto-identifiable, that is to say, all of them can be installed with no need for prior manual encoding, facilitating enormously the assembly and subsequent modifications to the installation.

SMOKE DETECTOR A30XH

Conventional smoke detector for fire detection. The A30XH detector is based on the Tyndall effect (light refraction in a dark chamber) for detection of fires which generates smoke (plastic, wood, paper, etc). The A30XH detector (smoke-heat detector) also has a static heat element that sets the detector into an alarm mode when temperature reaches 55ºC Features • Low section, total height less than 45 mm (including the base). • Available with high base for electrical conduit of 20 mm. • Alarm with two red LED, which makes easier the identification from any direction (360º). • Possibility to connect a remote action indicator. • Easy connection, without polarity. • Double flash LED indicates a dirty status of the detector (fast signal indicates alarm and slow indicates maintenance required). • Detector and base with easy installation, interchangeable with the entire of range A30X, and manufactured in white heat-resistant ABS. • According to EN 54-7 and CE mark according to European Regulation of Construction Products (UE) Nº305/2011.

SMOKE DETECTOR A30XHS

Conventional smoke detector for fire detection. The A30XH detector is based on the Tyndall effect (light refraction in a dark chamber) for detection of fires which generates smoke (plastic, wood, paper, etc). Features • Low section, total height less than 45 mm (including the base). • Available with high base for electrical conduit of 20 mm. • Alarm with two red LED, which makes easier the identification from any direction (360º). • Possibility to connect a remote action indicator. • Easy connection, without polarity. • Double flash LED indicates a dirty status of the detector (fast signal indicates alarm and slow indicates maintenance required). • Detector and base with easy installation, interchangeable with the entire of range A30X, and manufactured in white heat-resistant ABS. • According to EN 54-7 and CE mark according to European Regulation of Construction Products (UE) Nº305/2011.

A30XV COMBINED HEAT DETECTOR

Combined heat detector for fire detection. The detector A30XV has a double heat detection system that measures the speed of increase in temperature (rate of rise heat function), both as their absolute value (heat function), and compares it with a measure of internal reference. The rate of rise heat function allows to detect a fire in the early stages of their development, or, if this is very slow, is activated when the temperature reaches 55 °C. Features • Low section, total height less than 45 mm (including the base). • Available with high base for electrical conduit of 20 mm. • Alarm with two red LED, which makes easier the identification from any direction (360º). • Possibility to connect a remote action indicator. • Easy connection, without polarity. • Detector and base with easy installation, interchangeable with the entire of range A30X, and manufactured in white heat-resistant ABS. • According to EN 54-5 Class A2R (detectors with rate of rise heat function), and CE mark, according to the European Regulation of Construction Products (UE) N°305/2011.

A30XT HEAT DETECTOR

Conventional heat detector for fire detection. The detector consists of a sensitive element to temperature variations produced by any process of combustion. The value measured by this element is compared with a preset reference value which causes the heat detector to alarm status when the temperature reaches 55°C . Features • Low section, total height less than 45 mm (including the base). • Available with high base for electrical conduit of 20 mm. • Alarm with two red LED, which makes easier the identification from any direction (360º). • Possibility to connect a remote action indicator. • Easy connection, without polarity. • Detector and base with easy installation, interchangeable with the entire of range A30X, and manufactured in white heat-resistant ABS. • According to EN 54-5 class A2, and CE mark, according to the European Regulation of Construction Products (UE) N°305/2011.

MANUAL CALL POINT PUCAR

Manual call point for the conventional fire detection system. It has an indicator of action (red led) that illuminates in case of be manually operated (alarm). Features • Resettable call point by pushing yellow button on the front side. • Transparent protector cover to avoid accidental false alarms. • Immediate visual recognition of alarm status by the permanent activation of the LED, and the trigger of the yellow tab on the lower side of the activation face. • According to EN 54-11 and CE mark according the European Regulation of Construction Products (UE) Nº305/2011.

London control panel for fire detection system.

The London control Panel has been designed according EN54 part 2 and 4 in accordance with the last directives, successfully overcoming the most severe tests of environmental conditions, conducted electrical noise, magnetic disturbances, vibration, etc. Based in a micro processed technology of 16 bits, used this for managing the detection system and performed maneuvers. Features • Control panel configurable up to 12 modules, with 4 zones or 4 relays (control panel limit of 48 outputs, relays and zones). • Expandable up to 32 modules with an additional cabinet (limit 128 outputs, zones and relays). • Supports up to 32 devices (detectors and call points) per zone. • Configurable with PC-EASYLondon software (RS232). • It allows to connect an external keyboard (standard PC-PS2). • It allows the connection of 10 repeaters. • 30Vdc auxiliary output. • Equipped with 1 delayed sounder output (0 to 10 minutes) and supervised. • Equipped with 1 alarm output and 1fault output as free voltage relays. • It allows the connection of a printer (RS232). • Certified according EN 54-2 and EN 54-4, and CE mark. • Access to the panel keyboard by means of a numeric code.

SMOKE HOME DETECTOR

Autonomous domestic smoke detector for fire detection, with acoustic alarm. Smoke sensibility 0.08~0.15 dB/m Temperature sensibility 57ºC (model with temperature sensor) Standby current 8 ?A Alarm current 15 mA Temperature 0ºC to 50ºC Humidity 0 to 95% HR Acoustic alarm level 85 dB / 3 m Dimensions Ø105 x 30 mm Installation requirements: • Centre of roof (do not install less than 10 cm from the walls). Minimum installation recommended: • At least 2 detectors by house. • At least 1 detector by floor. • Separator hallway outside the open bedrooms. • Bedrooms normally closed. • On the roof before a stair. • Living room, dinner room, attic, etc.